XM-A6J9-0409D
XR-A6J9-0409D RoHS



Switch, PE42525 [PCB: 0456]
Recommended Bias Controller: XM-A6K1-0409D-SP

Configurations

Configurations

Configurations

Unit of Measure

Product Page

N/A pSemi

Spec Sheet

N/A PE42525

Low Freq

N/A 0.009 MHz

High Freq

N/A 60000 MHz

IL

N/A 4 dB

P1dB

N/A 35 dBm

IP3

N/A 46 dBm

 

N/A

Bias Instruction

N/A Power-up Sequence
1. Apply Control Voltage to V1 and V2
(-3.0V = Low, +3.0V = High)
2 Apply the RF input signal

Power-down Sequence
1. Turn off the RF input signal
2. Adjust V1 and V2 to 0V

RoHS

N/A XR-A6J9-0409D